Wiring Diagram N8700-DESP
The temperature probes are mounted directly to the heat
pad and can only be tested with a meter that can read type J
thermocouples. When testing the probe read the temperature
of the hot food well.
When replacing the well not to apply pressure directly to the
pad.
Heater Resistance:
208 Volt Heaters Min 82.65 ~ Max 91.35
240 Volt Heaters Min 109.20 ~ Max 120.80